Please use this identifier to cite or link to this item: http://archives.univ-biskra.dz/handle/123456789/2526
Title: FAULT DIAGNOSIS FOR INDUCTION MOTOR ROTOR BROKEN BAR BASED ON THE COMPARATIVE ANALYSIS OF CLASSICAL AND FUZZY PI REGULATORS FOR THE INDIRECT FIELD ORIENTED CONTROL
Authors: Samir MERADI
Abdelhamid BENAKCHA
Arezki MENACER
Keywords: broken rotor bars, Field Oriented Control, Fuzzy logic controller, Induction motor, multiphase winding.
Issue Date: 9-May-2014
Abstract: A fault diagnosis method was presented for motor rotor broken bar fault based on the comparative analysis of Fuzzy logic and classical (proportional-integral) control techniques. We propose the modeling of the diagram multi windings of the induction motor allowing apprehending his behavior in presence or absence of failures. We were interested in the indirect field oriented control of the induction motor using regulators classical and fuzzy logic (PI) by taking account of the presence of the broken rotor bars.
URI: http://archives.univ-biskra.dz/handle/123456789/2526
Appears in Collections:Communications Nationales

Files in This Item:
File Description SizeFormat 
CN 06_MERADI SAMIR.pdf445,72 kBAdobe PDFView/Open