Title: CRACK WIDTH DETERMINATION FROM EDDY CURRENT NON DESTRUCTIVE TESTING SIGNAL BY USING THE FVM METHOD
Authors: A. CHERIET
S. M. MIMOUNE
M. FELIACHI
B. HELIFA
Keywords: EC NDT, Finite volume method, Inverse problem
Issue Date: 24-Apr-2013
Abstract: This paper demonstrates a new field of application of the finite volume method (FVM). Due to its simplicity and efficiency in several electromagnetic problems, in this paper the FVM is adapted for solution of inverse eddy current non destructive testing (EC NDT) problems. A computer code involving crack size determination is developed and tested by a JSAEM benchmark problem
URI: http://archives.univ-biskra.dz/handle/123456789/2444
Appears in Collections:Communications Nationales

Files in This Item:
File Description SizeFormat 
Cn 28 cheriet_.pdf187,87 kBAdobe PDFView/Open